The Allen-Bradley 2711-T10C1 is a classic PanelView 1000 operator terminal, a 10.4-inch color touchscreen HMI used through the late 1990s and 2000s on SLC 500, ControlLogix, and CompactLogix-driven machines. It runs PanelBuilder32 application files and remains in service on a large installed base of US plant equipment.
Because the original PanelView 1000 hardware is end-of-life, most replacement work today involves either swapping a working used unit, or migrating to a PanelView Plus 7 / Plus 6 form-factor equivalent that retains the 10-inch cutout. This page covers the specs of the original 2711-T10C1 and the current spare and migration paths Rabwellplc keeps in stock.
| Parameter | Specification |
|---|---|
| Catalog number | 2711-T10C1 |
| Family | PanelView 1000 (classic) |
| Display | 10.4 in color CRT/active-matrix (catalog-dependent revision) |
| Resolution | 640 x 480 (VGA) |
| Operator interface | Touch screen |
| Network communication | Remote I/O (RIO) on Belden 9463 twinaxial - "C1" suffix = Remote I/O network port |
| Maintenance port | RS-232 (DF1) for PanelBuilder32 application upload/download |
| Print port | RS-232 print output |
| Application memory | 1008 KB nonvolatile / 310 KB application RAM (per Rockwell publication 2711-TD007) |
| ATA memory card | Supported |
| Application tool | PanelBuilder32 |
| Supply voltage | 85 - 264 V AC, 47 - 63 Hz |
| Power consumption | Approx. 75 W |
| Operating temperature | 0 degC to +55 degC |
| Storage temperature | -25 degC to +70 degC |
| Humidity | 5% to 95% non-condensing |
| Front panel rating | NEMA 4 / 4X (indoor) / 12 / 13, IP65 |
| Mounting | Panel mount with stud-and-clip retention |
| Cutout dimensions | Approx. 291 x 226 mm (11.46 x 8.90 in) |
| Approvals | UL Listed, CSA, CE, Class I Div 2 (revision-dependent) |
The "T" in the catalog number indicates a touch-only unit (no keypad), and the trailing "C1" identifies the Remote I/O network port. Other PanelView 1000 catalogs cover the same hardware with different network options: C3 = DH-485, C8 = DH+, C10 = DeviceNet, C15 = ControlNet, C16 = RS-232 (DF1), and C20 = EtherNet/IP. The maintenance RS-232 port for application download is present on every 1000-class PanelView regardless of the network suffix.
| Segment | Meaning |
|---|---|
| 2711 | PanelView Standard family |
| T10 | Touch screen, 10.4 in display |
| C | Color display |
| 1 | Remote I/O (RIO) network port |
| Generation | Example catalog | Display | Comms | Status |
|---|---|---|---|---|
| PanelView Standard 1000 (RIO) | 2711-T10C1 | 10.4 in color VGA | Remote I/O | End of life |
| PanelView Standard 1000 (DH+) | 2711-T10C8 | 10.4 in color VGA | Data Highway Plus | End of life |
| PanelView Standard 1000 (DF1) | 2711-T10C16 | 10.4 in color VGA | RS-232 DF1 | End of life |
| PanelView Plus 1000 | 2711P-T10C4D8 | 10.4 in color SVGA | EtherNet/IP, RS-232 | Active (legacy) |
| PanelView Plus 6 1000 | 2711P-T10C22D9P | 10.4 in color | EtherNet/IP, USB | Active |
| PanelView Plus 7 Performance 10" | 2711P-T10C22D8S | 10.4 in color, multi-touch | EtherNet/IP dual | Active, current |
If you are doing a like-for-like replacement and you can keep the existing PanelBuilder32 application running, a tested 2711-T10C1 is the cleanest option. If the project allows for a controls upgrade, the 2711P-T10C22D8S PanelView Plus 7 fits a similar 10-inch cutout and runs FactoryTalk View ME applications, which is the current Rockwell tool chain.
Most of our 2711-T10C1 demand is replacement-driven. We carry tested classic PanelView 1000 units when they come through, plus current PanelView Plus 6 and Plus 7 spares for migration projects, all under our Allen-Bradley program. Each unit ships bench-checked with the touchscreen, backlight, and serial port verified. If your project is moving to ControlLogix or CompactLogix, our application desk can match the HMI to the right 1756 ControlLogix or CompactLogix CPU at the same time.
Send your existing PanelBuilder32 application file and we will tell you whether a like-for-like swap or a Plus 7 migration is the better path for your shutdown window.
Check 2711-T10C1 replacement / migration stock ->
Is 2711-T10C1 still manufactured?
No. The PanelView 1000 classic series is discontinued. Replacement is by tested used units or by migration to PanelView Plus 6 / 7.
Can a PanelView Plus 7 drop into the same panel cutout as a 2711-T10C1?
The 10-inch PanelView Plus 7 and Plus 6 are designed to fit the same nominal 10-inch HMI cutout, but the exact bezel profile and stud pattern differ slightly. Always check the dimensional drawing against your panel before committing to the swap.
What software is needed to edit the application?
PanelBuilder32 for the original .pba file. To migrate to a PanelView Plus, the application must be converted to FactoryTalk View ME using the Rockwell legacy import tool, then cleaned up by hand.
Which PLCs does the C1 network port support?
The C1 suffix designates Remote I/O. It connects natively to PLC-5 processors and to SLC 500 chassis equipped with a 1747-SN RIO scanner. ControlLogix systems join via a 1756-DHRIO module configured for Remote I/O. The C1 network does not support EtherNet/IP, DH-485, or DF1; those are different catalog suffixes (C20, C3, and C16 respectively) or a PanelView Plus.
How long can I expect a tested used 2711-T10C1 to last?
Realistically, a few years of reliable service if it has a solid backlight and clean touch overlay, but the platform itself is end-of-life. We recommend planning a PanelView Plus migration in parallel with any classic PanelView replacement.